BYD 102Ah 3.2V LiFePO4 Prismatic Cell - Grade A (Pack of 4)


Price:
Sale price$199.99

Description

Power your energy storage system with confidence using this BYD 3.2V 102Ah LiFePO4 Prismatic Cell – Pack of 4. Built by trusted lithium manufacturer BYD, these high-performance LiFePO4 battery cells deliver exceptional cycle life, safety, and efficiency—making them an ideal choice for solar storage, EV conversions, RVs, and DIY battery projects.

Each cell features a nominal voltage of 3.2V and a capacity of 102Ah, offering excellent energy density with a compact footprint. With a long-lasting cycle life exceeding 3000 cycles, ultra-low internal resistance, and support for up to 2.5C discharge rate, these prismatic cells ensure stable power delivery under demanding conditions.

  • Pack Includes: 4 x BYD 102Ah 3.2V LiFePO4 Prismatic Cells
  • High Capacity: 102Ah per cell with nominal 3.2V output
  • Extended Cycle Life: Over 3000 cycles at standard use conditions
  • High Discharge Performance: Up to 400A pulse discharge for 30 seconds
  • Fast Charging Capable: Supports up to 1C continuous charge/discharge
  • Built for Safety: Features low self-discharge, no memory effect, and stable performance with built-in safeguards
  • Dimensions: 160mm x 49.9mm x 116mm (H118.5mm including bolts)
  • Weight: 1.98±0.1kg per cell
  • Environmentally Friendly: Mercury-free, non-toxic, and recyclable

🔒 1-Year Warranty

We stand behind the quality of our LiFePO₄ (LFP) cells and offer a 1-Year Warranty that covers manufacturer defects. If your battery experiences a verified factory defect within this period, we will provide a replacement.

Terms:

Warranties apply only to the original purchaser and are non-transferable.

Warranty claims require proof of purchase, serial number verification, and test results.

A properly configured BMS is mandatory. Warranty is void if a BMS is not used or misconfigured.

✅ Covered Manufacturer Defects:

Internal short circuits due to factory defects.

Electrolyte leakage (not caused by physical damage).

Cells failing to meet advertised capacity under proper use.

Factory defects in welds or terminals.

❌ Not Covered:

Overcharging, over-discharging, or exceeding rated current.

Failure due to lack of a proper BMS or incorrect BMS settings.

Cells installed into pre-existing battery packs where failure results from pack imbalance or BMS issues.

Physical damage, including punctures, crushing, or exposure to heat/water.

Natural capacity fade due to aging and cycle life.

⚠ Important Safety Warnings

Improper handling or misuse of this Lithium Iron Phosphate (LFP) battery can result in ELECTRICAL DAMAGE, FIRE, or THERMAL RUNAWAY, causing personal injury, property damage, or equipment failure. Users must read and follow all safety guidelines before purchase and use. Click here to review the full safety guidelines.

  • Voltage Limits: Always operate within the recommended voltage range (2.5V–3.65V). Exceeding these limits can degrade performance, damage the cell, or pose safety risks.
  • Thermal Stability: LFP cells are thermally stable, but short circuits, overcharging, or physical damage can still cause overheating or failure.
  • Storage & Transport: Always store cells in protective cases or fully assembled battery packs with proper protection circuitry (BMS). Never store loose cells in bags or near conductive materials (e.g., tools, wires, or metal objects) that could contact the terminals and cause a short circuit. Store in cool, dry conditions away from physical or electrical hazards.
  • Inspection: Do not use if the battery casing, wrapper, or terminal is damaged, dented, leaking, or bulging. These are signs of instability and potential failure.
  • Charging: Use a smart charger specifically designed for LFP cells and ensure that the charger's voltage matches the battery's specifications. Monitor charging and avoid leaving batteries unattended.
  • Prohibited Activities:
    • Do not expose the battery to high heat, fire, or liquid.
    • Do not short circuit, puncture, crush, or modify the cell.
    • Do not charge or discharge beyond the manufacturer’s specified voltage range.
    • Do not dispose of in regular trash—always recycle responsibly.
  • Emergency Response: If the battery overheats, emits smoke, or swells, move it to a non-flammable surface (e.g., sand or concrete) and stop use immediately. In case of fire, use a Class D fire extinguisher or sand. Do not use water.

Disclaimer

IMR Batteries is not responsible for any damages, injuries, or claims arising from improper use, handling, or failure to follow these safety guidelines. Lithium Iron Phosphate (LFP) cells are designed for specific applications and must be integrated into systems with proper protection circuitry. We do not guarantee compatibility with any specific application, charger, BMS, or device. It is the customer’s responsibility to verify proper cell selection and compatibility before use. IMR Batteries is not responsible for the design, assembly, or safety of any battery pack built using our cells. It is the reseller's responsibility to ensure all safety warnings and product guidelines are effectively communicated to their customers. Users and resellers assume full responsibility for the safe handling, usage, and distribution of this product.

You may also like

Recently viewed